FIXED GAS DETECTORS AND FLAMMABLE GAS DETECTORS
Vanko provides best in class products that are second to none. Find out what makes these products the best in the industry.
Dräger POLYTRON 5100: ELECTROCHEMICAL DETECTOR FOR THE MEASUREMENT OF TOXIC GASES & O²
The Dräger Polytron 5100 EC is Dräger’s cost effective fixed gas detector. It uses the high-performance plug and play, long life electrochemical DrägerSensor™ to detect toxic gases and O².
Backlit display (3 wire only), status LED’s, and a 2 or 3 wire 4-20 mA analog output. Optional relay contacts (High, Low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window.
Dräger POLYTRON 5200: CATALYTIC BEAD DETECTOR FOR THE MEASUREMENT OF FLAMMABLE GASES
The Dräger Polytron 5200 CAT is a flame detector that detects flammable gases in the lower explosion limit (%LEL). It uses Dräger double compensating catalytic bead sensor which provides superior performance over conventional catalytic bead sensors.
Backlit display (3 wire only), status LED’s, and a 2 or 3 wire 4-20 mA analog output. Optional relay contacts (High, Low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window.
Dräger POLYTRON 5310: IR FLAME DETECTOR FOR THE MEASUREMENT OF FLAMMABLE GASES
The Dräger Polytron 5310 IR is an IR flame detector that detects flammable gases in the lower explosion limit (% LEL). It uses the Dräger PIR 3000 single beam, heated Infrared sensor that can be configured for methane, propane, or ethylene.
Backlit display (3 wire only), status LED’s, and a 2 or 3 wire 4-20 mA analog output. Optional relay contacts (High, Low & Fault) are available.
Dräger POLYTRON 5700: IR FLAME DETECTOR FOR THE MEASUREMENT OF FLAMMABLE GASES
The Dräger Polytron 5700 IR is an IR flame detector that detects flammable gases in the lower explosion limit %(LEL). It uses the high performance Dräger PIR 7000 dual beam, double compensating, heated infrared sensor which provides industry leading long-term performance specifications.
Backlit display (3 wire only), status LED’s, and a 2 or 3 wire 4-20 mA analog output. Optional relay contacts (High, Low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window. A built-in library allows automatic cross calibration for various flammable gases.
Dräger POLYTRON 5720: IR FLAME DETECTOR FOR THE MEASUREMENT OF CO²
The Dräger Polytron 5720 IR is an IR flame detector that detects CO² in percent volume or ppm. It uses the high performance Dräger PIR 7020 dual beam, double compensating, heated infrared sensor which provides industry leading long-term performance specifications.
Backlit display (3 wire only), status LED’s, and a 2 or 3 wire 4-20 mA analog output. Optional relay contacts (High, Low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window.
Dräger POLYTRON 8100: ELECTROCHEMICAL DETECTOR FOR THE MEASUREMENT OF TOXIC GASES & O²
The Polytron 8100 EC is Dräger’s top of line electrochemical detector. It uses the high-performance plug and play, long life electrochemical DrägerSensor™ to precisely detect toxic gases or O². Backlit display (3 wire only), status LED’s, and a 2 or 3 wire 4-20 mA analog output. Optional relay contacts (High, Low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window.
Optionally, Dräger Dongles can add additional capabilities including predictive maintenance and data logging. Other models are available with Modbus and Fieldbus protocols.
Dräger POLYTRON 8200 CAT: CATALYTIC BEAD DETECTOR FOR THE MEASUREMENT OF FLAMMABLE GASES
The Dräger Polytron 8200 CAT is an advanced flammable gas detector that detects hazardous substances in the lower explosion limit (%LEL). It uses the Dräger double compensating catalytic bead sensor which provides superior performance over conventional catalytic bead sensors.
Backlit display (3 wire only), status LED’s, and a 2 or 3 wire 4-20 mA analog output. Optional relay contacts (High, Low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window, or via HART™. Other models are available with Modbus and Fieldbus protocols.
Dräger POLYTRON 8310: IR FLAME DETECTOR FOR THE MEASUREMENT OF FLAMMABLE GASES
The Dräger Polytron 8310 IR is an IR flame detector that detects hydrocarbon gases in the lower explosion limit (%LEL). It uses the Dräger PIR 3000 single beam, heated Infrared sensor that can be configured for methane, propane, or ethylene.
Backlit display, status LED’s and a 3 wire 4-20 mA analog output with HART™ protocol. Optional relay contacts (High, low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window or via HART™. Other models are available with Modbus and Fieldbus protocol.
Dräger POLYTRON 8700: IR FLAME DETECTOR FOR THE MEASUREMENT OF COMBUSTIBLE GASES
The Dräger Polytron 8700 IR is an IR flame detector that uses the high performance Dräger PIR 7000 dual beam, double compensating, heated infrared sensor to provide industry leading long-term performance specifications.
Backlit display, status LED’s and a 3 wire 4-20 mA analog output with HART™ protocol. Optional relay contacts (High, low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window or via HART™. A built-in library allows automatic cross calibration for various combustible gases. Other models are available with Modbus and Fieldbus protocols.
Dräger POLYTRON 8720: IR FLAME DETECTOR FOR THE MEASUREMENT OF CO2
The Dräger Polytron 8720 IR is an IR flame detector that detects CO2 in percent volume or ppm. It uses the high performance Dräger PIR 7020 dual beam, double compensating, heated infrared sensor which provides industry leading long-term performance.
Backlit display, status LED’s and a 3 wire 4-20 mA analog output with HART™ protocol. Optional relays contacts (High, low & Fault) are available. Configuration & calibration are performed using a non-intrusive magnetic wand through the transmitter window or via HART™. Other models are available with Modbus and Fieldbus protocols.
Dräger POINTGARD 2100: ELECTROCHEMICAL DETECTOR FOR THE MEASUREMENT OF TOXIC GASES & O²
The Dräger PointGard 2100 series is a general-purpose area "Stand Alone" gas detection system. With the long life electrochemical DrägerSensor™, the PointGard 2100 accurately monitors toxic gases and O². Its rugged, water resistant housing comes complete with backlit display, horn, strobes, 4-20 mA output, relays and a built-in power supply.
Dräger PULSAR 7000: OPEN PATH FLAMMABLE GAS DETECTOR
The Dräger Pulsar 7000 series is a stationary open path flammable gas detector for the measurement of explosive hydrocarbons gases. The standard unit comes with a 4-20 mA analog output with HART™ protocol. A HART™ hand held terminal (HHT) or laptop is all that is required to align and set up the Pulsar 7000. The robust design and the extremely rapid response of the sensor make the Dräger Pulsar 7000 Series a dependable solution for your requirements in the oil and gas industry, as well as the chemical industry.
Dräger FLAME 3000: FLAME DETECTOR
The Dräger Flame 3000 flame detector uses a visual/Infrared measurement principle to detect flames. This fixed gas detector reduces false alarms or loss of sensitivity that can occur with conventional UV/IR & IR3 technologies. 4-20 mA analog output or relays.
Dräger FLAME 5000: FLAME DETECTOR
The Dräger Flame 5000 flame detector uses a visual/Infrared measurement principle to detect flames. This fixed gas detector reduces false alarms or loss of sensitivity that can occur with conventional UV/IR & IR3 technologies. 4-20 mA analog output with HART™ protocol or relays. The Flame 5000 also includes a built-in color video signal that is transmitted a over twisted pair. This can reduce costs by customers not requiring additional CCTV cameras to monitor an area. In addition, video of any fire events is logged on the on board datalogger.
We pride ourselves on representing only top quality global products with worldwide support.
Canadian Locations
Edmonton Head Office Sales & Service Inquiries 780-436-0281 4408 - 51 Ave. Edmonton, AB T6B 2W2 |
Calgary 403-219-3440 205, 4000 Glenmore Ct. SE Calgary, AB T2C 5R8 |
Coquitlam 236-335-4422 1303 Durant Dr. Coquitlam, BC V3B 6K6 |
Langley 778-877-7997 54, 7686 - 209 St. Langley, BC V2Y 0R5 |
Regina 306-250-1755 716, 2010 11 Ave., 7th Flr. Regina, SK S4P 0J3 |
Winnipeg 204-333-9856 179 Worthington Ave. Winnipeg, MB R2M 1R9 |
Sarnia 519-464-3270 2999 Delia Crescent Brights Grove, ON N0N 1C0 |
Toronto 289-314-8220 9-48 Three Valleys Drive N Toronto, ON M3A 3B5 |
St. Catherines 365-323-6443 St. Catherines, ON | Boucherville 514-606-5183 1235 Rue Gay Lussac Boucherville, QC J4B 7K1 |
Lévis 438-270-2789 2 Rue Saint Henri Levis, QC G6V 3G8 |
306-250-1755 716, 2010 11 Ave., 7th Flr. Regina, SK S4P 0J3 |
514-606-5183 179 Worthington Ave. Winnipeg, MB R2M 1R9 |
519-464-3270 2999 Delia Crescent Brights Grove, ON N0N 1C0 |
289-314-8220 9-48 Three Valleys Drive N Toronto, ON M3A 3B5 |
514-606-5183 1235 Rue Gay Lussac Boucherville, QC J4B 7K1 |
438-270-2789 2 Rue Saint Henri Lévis, QC G6V 3G8 |
Call Toll Free: 1-800-307-8554