Gas Measurements PDF Print E-mail
PROCESS ANALYZERS (GAS CHROMATOGRAH, FTIR)

AIT
Hamilton Sunstrand (AIT) delivers process analytical technology solutions to the leading companies of the world. They design and manufacture robust process development and on-line analyzers for quantitative and qualitative analysis.
www.hs-ait.com/Scripts/default.asp
HYDROCARBON DEWPOINT

Michell Instruments
Patented ‘dark spot’ principle chilled mirror technology for high sensitivity measurement of hydrocarbon gas dew-points. Fully automatic on-line analysis in a self-contained EExd enclosure with no purge air or external cooling requirements. Combines a rugged sensor element design with self-cleaning diagnostics to offer sensitivity in the order of 1ppm of condensate. Optional water and hydrocarbon dew-point analysis.
www.michell.co.uk/products/store/display/Condumax_II
GAS & VAPOUR MONITORING SYSTEMS

Control Instruments
Lower flammable limit (LFL or LEL), total hydrocarbon monitoring and Calorific value (BTU) analysers for the most demanding industrial applications. These are stand alone, fast response analyzers, fail safe in design and immune to contaminants, capable of measuring multiple solvent mixtures without re-calibration.
www.controlinstruments.com/index.html
FIXED GAS DETECTION: TOXIC & OXYGEN DEFICIENCY

Drager Safety
General Purpose to Explosion Proof stationary detectors for the continuous monitoring of various toxic gases and for reduced Oxygen atmospheres. Using state of the art microprocessor technology to convert electrochemical signals to analog, HART, or RS485 outputs. Driven via IR remote, push buttons or HART, the detectors offer ease of calibration and a variety of diagnostic and self test features.
www.draeger-safety.com
FIXED GAS DETECTION: INFRARED & CATALYTIC BEAD

Drager Safety
Stationary detectors for the continuous monitoring of combustible gases and vapours. Incorporating either catalytic bead or Infrared technology, they can be either explosion proof or intrinsically safe units using analog, HART, or RS485 signal outputs. Operated with or without local display and/or relays, the detectors offer ease of calibration, continuous self test routines and fail safe operation. SIL2 systems can be designed with the IR334.
www.draeger-safety.com
OPEN PATH COMBUSTIBLE GAS DETECTION

Drager Safety
Open path gas detectors for the continuous monitoring of combustible gases and vapours along a line of sight between an optical transmitter and a receiver. Infrared technology using four high powered pulsating Xenon lamps makes the detector immune to sunlight, stack flares, arc-welding and other high energy IR sources. Environmental conditions such as fog, mist or snow are compensated by increasing the intensity and the flash rate of the light sources.
www.draeger-safety.com
MOISTURE ANALYZERS

Kahn
A wide range of transmitters, instruments and system solutions capable of measuring trace moisture, humidity and dew-point for industrial applications such as oil & gas pipelines, compressed air and power generation. The range of sensors and analyzers includes high accuracy cooled mirror and fast response ceramic based impedance technology plus a range of calibrator/generators for the complete analysis package.
www.kahn.com/hygrometers/index.html
TUNEABLE LASER DIODE ANALYZERS

Neomonitors
Employing the measurement principle known as ‘single line spectroscopy’, the near infrared tunable laser diode analyzers offer a broad range of very low level gas measurements. Mounting options include insitu, extractive, open and multi path variations. The measurement technology offers high sensitivity and signal transmission, no cross interference issues, fast response and only annual calibration requirements. Rated to CSA Class 1, Div 2 as a standard.
www.neomonitors.com/products/
PROCESS GAS ANALYZERS: FIXED & PORTABLE

Servomex
A full range of process gas analysis instrumentation utilizing technology such as zirconia dioxide for combustion control applications, paramagnetic technology for process Oxygen applications and a range of Infrared analyzers for various industrial gas applications. The analyzer range includes portable, bench top, 19” rack and wall mounting units for single and multi-component high accuracy gas measurements in process applications from general purpose to class 1, division 1.
www.servomex.com/Servomex.nsf/GB/products_home.html
PORTABLE AND FIXED FLUE GAS MEASUREMENTS
 
Madur
Portable flue gas analysers. From lightweight, low-cost units for O2 and CO up to top-of-the-range industrial equipment fitted with up to 9 gas sensors. Our analysers use a mixture of electrochemical and NDIR sensors. Of course, even the smallest analyser calculates all the relevant combustion parameters.
www.madur.com
 